NTIPL’s integrated Smart Data Center Solutions yields remarkable ROI for a leading Textile Company of India
Network Techlab Assisted Welspun – A Leading Textile Company with Smart Data Center Modular and Scalable Concept That Helped To Save Their Allotted CAPEX & Space.
Organization:
WELSPUN Corp Limited
Location:
Hyderabad, India
Domain:
Textile Company
Solution Offered:
Data Center Solutions (Smart Data Center)
Overview:
Welspun Group is one of India’s fastest-growing global conglomerates with businesses in Line Pipes, Home Textiles, Infrastructure, and Steel. As globally recognized leaders in Home Textiles and Line Pipes, they have a presence in over 50 countries with a strong team of 26,000+ employees and over 100,000 shareholders. Its clients include companies operating in the Oil and Gas and Retail sectors such as Chevron, ExxonMobil, Walmart, and Target. Welspun provides many jobs in India improving employment.
Requirement:
- Greenfield Project with faster implementation at Hyderabad remote offshore location
- IT Room proposed area was larger than the actual requirement for the ITE
- The larger room was increasing both the CAPEX and OPEX for a conventional Legacy Data Center
- Involvement of multiple vendors, multiple coordination & thereby increasing project timeline
- Scalability for future expansion was a challenge considering Conventional Data Center and present load condition
Solutions:
- Vertiv Smart Solution with integrated Rack and In Row cooling with inbuilt Security systems
- Smart Cabinet, Racks 3#, External UPS, Cooling Unit, Fire Suppression & Access, RDU
- Dedicated rack-based cooling & fire suppression, helped to save 2/3rd of room volume & hence energy spent, costly NOVEC gas and interior work – saving both CAPEX and OPEX
- Saving on immediate CAPEX helped to convince existing users
Smart Solution Comparison with Legacy Data Center:
Performance Parameters | Smart Solution | Conventional Legacy Data Centre |
Cooling Approach | Dedicated Rack level In-row Cooling, with capacity modulation | Room Level Cooling |
Power Availability | Provision for Rackmount UPS solution along with a battery | Separate Provision has to be made in Conventional system |
Installation & Commissioning | Independent of the Site location takes less than a week | Site dependent takes more than 8 weeks |
Reduced Go Live Time | No wet work at the site manufactured at the factory and assembled at site consistent quality | |
Fire detection & Suppression | Integrated Fire detection & Suppression, Designed exclusively for Smart Solutions | Room Level Fire Detection and Suppression (Expensive) |
Monitoring | Rack-mounted Integrated Intelligent monitoring | Have to depend on Separate Monitoring arrangement |
Reduced Operational Cost through Monitoring | Remote Monitoring for Health, Performance and Utilization Reduction through resources saving | |
Space Utilisation | No Raised Floor requirement, takes optimal Space Integrated Cabinet approach,
High density with flexibility can grow with your business |
Raised Floor / Ceiling is required |
Modularity | It is offering with high modularity to suit future changes | Design is site-dependent & varies from case to case basis |
Access Control | Provides Integrated Biometric Access control which offers better security | The separate arrangement is required for providing access control |
Relocation | Possible, Very Easy, Relocation with 100% Parts | 100% Parts movement may not be possible |
Freedom to mount the solution | It Can be installed in any environment | Separate Room is required |
Magnetic Lock door | Magnetic lock door which will open automatically in case of emergency | No such provision will require a separate arrangement |
Energy Efficiency | Digital scroll technology cooling, design optimization makes it energy efficient Solution. Digital Scroll cooling Technology – Variability from 20% to 100% Containment Approach (Cold aisle & Hot aisle containment) |
Depends on the overall design of DC facility |
Results:
- Smart Solution with modular and scalable concept helped to save their allotted CAPEX & Space
- Energy-saving through both Hot & Cold Aisle containment is more than single Hot or Cold Containment
- RDU based monitoring helped to connect with Global team and facilitate remote access
- Centralized monitoring enabling comprehensive reports to share with global management